INNOLOG DRY ICE Certified traceability for transport using dry ice
SINGLE-USE TEMPERATURE LOGGER
The Innolog Dry Ice is designed to monitor and record ultra-low temperatures during the transport of cryosensitive products using dry ice. Certified to DO160 and IATA PI970 II, it guarantees traceability in accordance with the most stringent pharmaceutical, medical and biotechnology requirements.
Your solution for extreme temperatures
INNOLOG DRY ICE, DESIGNED FOR CRYOGENIC CONDITIONS
The Innolog Dry Ice meets the requirements of professionals who transport products that need to be kept at very low temperatures. Equipped with a high-precision internal RTD sensor and an LCD screen, it provides real-time readings and full traceability from the moment it is activated.
- Extreme accuracy: Internal RTD sensor accurate to ±0.5°C between -20°C and +40°C, and ±1°C beyond that range. Designed to operate reliably down to -80°C.
- Real-time display: Built-in LCD screen showing the current temperature, statistics (max, min, average, MKT), alarm status and battery level at all times.
- Traceability: 2 detachable labels with a unique barcode for unambiguous identification with every consignment.
- Air transport compliance: Certified to DO160 and IATA PI970 II, the Innolog Dry Ice is approved for air transport whilst actively using dry ice.
- Traceability: comprehensive. Automatic generation of PDF and CSV reports via USB connection. The validation certificate is stored directly in the device’s memory. List item
Markets & Applications
FOR WHICH SECTORS IS THE INNOLOG DRY ICE DESIGNED?
Pharmaceutical & Medical
Transport and storage of vaccines, biological medicines, blood samples and tissues requiring a temperature below -20°C.
Laboratories & Research
Monitoring of storage conditions for reagents, cell cultures and experiments requiring a controlled cryogenic environment.
Biotechnology industry
Traçabilité des matières premières biologiques, des ADN/ARN et des produits de thérapie génique pendant leur acheminement.
Dry Ice Transport
Continuous tracking of domestic and international shipments using dry ice as a refrigerant, in compliance with IATA regulations for air transport.
Main features
Temperature range
from -90 °C to +70 °C
Secure data files
Automatic generation of encrypted PDF and CSV reports
USB 2.0 interface
for fast data transfer
Memory capacity
up to 8,640 registration points
Autonomy
up to 30 days at temperatures below -80°C
High precision
up to ±0.5 °C




Why choose Innolog?
- Certified for air transport with dry ice
The Innolog Dry Ice is one of the few data loggers to hold DO160 and IATA PI970 II certifications, which authorise its use during air shipments involving dry ice. This is an essential requirement for international pharmaceutical and biotechnology shipments.
- Instant reading on the LCD screen
Unlike data loggers without a display, the Innolog Dry Ice allows you to view the current temperature, the recorded maximum and minimum values (max/min), the MKT and the alarm status in real time. No connection to a computer is required for a quick check whilst in transit.
- Automatic shutdown when connected via USB
When the logger is connected to the computer, it stops automatically and generates PDF and CSV reports without any further action being required. The validation certificate is stored directly in the device’s memory.
- Long-term storage prior to use
With a shelf life of up to 16 months before use, Innolog Dry Ice can be ordered from stock and used as and when required, without any short-term expiry constraints.
FAQ – Frequently Asked Questions about Innolog Dry Ice
What is the temperature range of the Innolog Dry Ice?
The Innolog Dry Ice operates between -80°C and +65°C. Its accuracy is ±0.5°C between -20°C and +40°C, and ±1°C outside this range.
Is Innolog Dry Ice approved for air transport?
Yes. It is DO160 and IATA PI970 II certified, which authorises it to operate in active mode during air transport using dry ice. This is a specific requirement for pharmaceutical and biotechnology air shipments.
How do I get the temperature report?
Connect the Innolog Dry Ice to a computer’s USB port. The device will switch off automatically and generate a PDF report and a CSV report. The validation certificate can also be accessed from the device’s memory.
How long can the device record for?
The Innolog Dry Ice can record data for up to 30 days at 5-minute intervals, which equates to up to 16,000 data points.
Can the device be stored before use?
Yes. Innolog Dry Ice can be stored for up to 16 months before use, which allows you to maintain a buffer stock without the risk of losing calibration.
What is the difference between Innolog Dry Ice and Innolog Pro?
The Innolog Pro is designed for standard cold chain temperatures (from -30°C to +70°C) and is DO-160G certified for air transport. The Innolog Dry Ice is specially designed for the ultra-low temperatures (down to -80°C) associated with the use of dry ice. It is also IATA PI970 II certified, which is mandatory for air shipments using dry ice. The two products complement each other depending on the nature of the goods being transported.
Contact Us
Have a project, a question, or need information?
Our team is here to listen to you, support you and meet your needs.
Please fill in the form opposite and we will get back to you as soon as possible.
- Fast and Personalized Response
- Expert Guidance
- Solutions Tailored to Your Challenges
- Comprehensive Request Tracking
Need more information?
Responsive and Personalized After-Sales Service
Response Time
For All Your Technical Inquiries